Customization: | Available |
---|---|
Product Name: | Drone Detection and Jamming System Integrates Dete |
Operating Frequency Range: | 50MHz-6GHz |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Detection parameter | |
Detection range | 50MHz~6GHz |
Detection Radius | ≥5000m(according to environment) |
Real-time processing bandwidth | 160MHz |
Distance measurement accuracy | ≤10%R |
Horizontal range | 0-360° |
Interference parameters | |
Interference frequency band 1 | (830-930)±5MHz,50W |
Interference frequency band 2 | (1547-1628)±5MHz,20W |
Interference frequency band 3 | (2398-2510)±5MHz,100W |
Interference frequency band 4 | (5702-5887)±5MHz,100W |
Interference frequency band 5 | 433MHz(410-470),50W |
Interference frequency band 6 | (5128-5381)±5MHz,50W |
Interference frequency band 7 | (1180-1286)±5MHz,20W |
Interference frequency band 8 (Optional) |
5.5G(5500-5630) |
Defense distance | 1000m-3000m (according to environment) |
Response time | ≤3s |
operating system | |
Whitelist | Yes |
Unattended | Yes |
Data storage | Yes |
Signal recording | Yes |
Sound and light alarm function | Yes |
Machine parameters | |
Protection level | IP65 |
Dimension | Chassis: 410*520*240mm Antenna:800mm |
Weight | Chassis: 28KG Antenna: 3.5KG |
Maximum power consumption | Detection≤70W;Jammer<1500W |
Working temperature | -30°~60° |
A. Connect the network cable to the switch;
B. Connect the device and the operation terminal to the same switch (if the distance between the detection host and the operation computer does not exceed 30 meters, you can also connect the network cable directly to the detection host and the operation computer);
C. Plug in the power supply of the host (note that a three-phase power cable should be used. In addition to the hot wire and the neutral wire, there should be a ground wire, which is well grounded)
D. Set the address of the operation terminal and the outdoor host of the device on the same network segment according to the switch's website address;
E. The network needs to be tested for connectivity. You need to enter ping+device address (default 192.168.2.6) on the operation terminal (default 192.168.2.100). Only if it is connected, it is qualified.
F. After the connection is completed, start the computer and chassis host one by one.
G. The transmission range of the network cable is roughly 30 meters to 50 meters. If it exceeds, a switch relay is required to enhance the network signal.